DR34 Compensated

DR34 Compensated Detector circuit overlay

DR34 Compensated Detector circuit overlay

DR34 Compensated Thermopile

DR34 Compensated Thermopile

Features
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.

Applications
Industrial and medical monitoring including infant incubators.

Benefit
Compensated rectangular shaped active area in a TO-5 package with moderate output.

Options

  1. See Standard Windows and Filters (PDF) for list of optical filter options
  2. See Thermopile Configuration Table for more options.

Datasheet
For more detailed information see the datasheet DR34 Compensated (PDF).

DR34 Thermopile Detector Technical Specifications

Specifications apply at 23°C with KBr Window and Argon encapsulating gas

Parameter Min Typical Max Symbol Units Comments
Active Area size   3.16 x .4   AA mm Hot junction size, per element.
Element Area   1.264   A mm2  
Number of Junctions   40       Per element.
Number of Channels   1 Compensated       Per detector package.
Output Voltage 90 115 130 Vs μV DC,  H=330μW/cm2 (3)
Signal-to-Noise Ratio 4,545 7,099 11,404 SNR √Hz DC, SNR=Vs/Vn
Responsivity 21.6 27.6 31.2 V/W DC, =Vs/HA  (2)
Resistance 8 16 24 R Detector element
Temperature Coefficient of   -.36     %/°C Best linear fit, 0° to 85°C (1)
Temperature Coefficient of  R   -.2     %/°C Best fit, 0° to 85°C (1)
Noise Voltage 11.4 16.2 19.8 Vn nV/√Hz Vn2=4kTR
Noise Equivalent Power .37 .59 .92 NEP nW/√Hz DC,  NEP= VnHA/Vs (2)
Detectivity 1.2 1.9 3.1 D* 108√Hz/W DC,  D*=Vs/ VnH√A  (2)
Time Constant   38   Τ ms Chopped, -3dB point (1)
Field of View   NA   FOV Degrees See Assembly Drawings for FOV Description.
Package Type   TO-5 with 3 Pins       Standard package hole size:Ø.180"
Operating Temperature -50   100 Ta °C  

General Specifications: 
Flat spectral response from 100nm to > 100µm.  Linear signal output from 10-6 to 0.1W/cm2
Maximum incident radiance 0.1W/cm2 , damage threshold ≥ .5W/cm2

Notes:      
(1) Parameter is not 100% tested. 90% of all units meet these specifications.
(2) A is detector area in cm2.
(3)Test Conditions: 500K Blackbody source; Detector active surface 10cm from 0.6513cm Diameter Blackbody Aperture.