ST120 Dual

ST120 Dual Detector circuit overlay

ST120 Dual Detector circuit overlay

ST120 Dual Thermopile Detector

ST120 Dual Thermopile Detector

Features
A two-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/°C. This detector has a very short thermal shock response to ambient temperature change.

Applications
Excellent for gas analysis, fire suppression, non-contact temperature, and horizon sensor .

Benefit
Low cost with high output.

Options

  1. See Standard Windows and Filters (PDF) for list of optical filter options
  2. Internal 30kΩ 5% NTC chip thermistor provides ambient package temperature measurement. See DC-4005 section of Thermistor Options (PDF).
  3. Internal aperture precisely defines active area for applications with FOV and/or spot size requirements. See Aperture Options (PDF) for available sizes.
  4. See Thermopile Configuration Table for more options.

Datasheet
For more detailed information see the datasheet ST120 Dual (PDF).

Parameter Min Typical Max Symbol Units Comments
Active Area size   1.2 x 1.2   AA mm Hot junction size, per element.
Element Area   1.44   A mm2  
Number of Junctions   80       Per element.
Number of Channels   2       Per detector package.
Output Voltage   165   Vs μV DC,  H=330μW/cm2 (3)
Signal-to-Noise Ratio   4,301   SNR √Hz DC, SNR=Vs/Vn
Responsivity   34.7   V/W DC, =Vs/HA  (2)
Resistance   90   R Detector element
Temperature Coefficient of   -.04     %/°C Best linear fit, 0° to 85°C (1)
Temperature Coefficient of  R   .02     %/°C Best fit, 0° to 85°C (1)
Noise Voltage   38.4   Vn nV/√Hz Vn2=4kTR
Noise Equivalent Power   1.10   NEP nW/√Hz DC,  NEP= VnHA/Vs (2)
Detectivity   1.09   D* 108√Hz/W DC,  D*=Vs/ VnH√A  (2)
Time Constant   25   Τ ms Chopped, -3dB point (1)
Field of View   27°/77°   FOV Degrees See Assembly Drawings for FOV Description.
Package Type   TO-5       Standard package hole size: Ø.150"
Element Matching   25   M % M=|VA-VB|/VB (2)
Element Separation   3.30     mm Center to Center
Operating Temperature -50   125 Ta °C  

General Specifications: 
Flat spectral response from 100nm to > 100µm.  Linear signal output from 10-6 to 0.1W/cm2
Maximum incident radiance 0.1W/cm2 , damage threshold ≥ .5W/cm2
Notes:      
(1) Parameter is not 100% tested. 90% of all units meet these specifications.
(2)
A is detector area in cm2.
(3)
Test Conditions: 500K Blackbody source; Detector active surface 10cm from 0.6513cm Diameter Blackbody Aperture.

Product Finder

Product Comparison Guide

The Gold Standard

The Collaboration Station

Contact Us